Mexico Region Injuries 1996 January 05, 1996 - DelMar Operating, Inc.
Remarks: The platform operator was warming up (idling) the gas compressor engine when the final discharge piping exploded and a small flash fire occurred. The flash fire extinguished itself immediately. One operator was passing near the compressor piping when the explosion occurred, resulting in minor injuries to the eyes and face and ringing in the ears. January 14, 1996 - Mobil Oil Exploration & Producing NA, Inc
Remarks: An electrician was helping repair a crane engine throttle control. He stepped from a skid beam down onto uneven grating and twisted his right ankle. January 21, 1996 - Hardy Oil & Gas USA Inc.
Remarks: Prior to opening the well (on a 10/64 choke with 5,458 psi), portable test equipment piping was pressure tested to 4,000 psi. The manifold choke was increased to 12/64 with 6,125 psi and then again to 14/64. Simultaneously, the heater choke was increased from 22/64 to 24/64, resulting in the decrease in heater pressure. Immediately following the above choke adjustments, an elbow in the flowline piping between the choke manifold and the heater ruptured. The supervisor and field tech. were both struck in the leg causing lacerations. The ESD activated and shut in the well at surface. January 24, 1996 - Amoco Production Company
Remarks: Pulled muscle in groin while lifting materials. January 26, 1996 - Amoco Production Company
Remarks: Lifting on fill-up line and strained back. January 30, 1996 - Energy Development Corporation
Remarks: Cable broke dropping the bell nipple 29' on deck injuring an employee. February 04, 1996 - Chevron U.S.A. Inc.
Remarks: A SS tubing drain line was being installed. The worker started to stand, and his left knee popped. February 15, 1996 - Total Minatome Corporation
Remarks: Platform operators were sitting in front of the operator's desk located in the southeast corner of the living quarters at approximately 0530 hours when the giatronic box exploded. It is believed that the explosion occurred due to the ignition of a possible chemical leakage and build-up of hydrogen from a 12Vdc/55AH sealed battery inside the airtight-sealed giatronic box. Following the explosion, the battery, estimated to be approximately 10 pounds in weight, fell from the shattered giatronic box onto an operators lower back. He and a coworker immediately exited the east doorway of the living quarters following the explosion. Both returned to the area of the explosion within minutes, and an investigation revealed that damage was limited to the giantronic box and no additional fire damage was evident. March 06, 1996 - CNG Producing Company
Remarks: The captain was walking downstairs to the galley when he lost his footing around the middle rung. He fell to galley floor complaining of pain. The result was 3 broken ribs and a punctured lung. March 08, 1996 - Mobil Exploration and ProducingNA, Inc
Remarks: An employee was descending steps, missed a step, and fell to floor. March 30, 1996 - Shell Offshore Inc.
Remarks: An operator was working on the crane boom ram preparing it for the welder. He was taking out the pressure relief valve from the ram block using a 12" pipe wrench, placing his hand on the wrench by his shoulder, and pushing upward. Motion resulted in a slight tweak and pain in lower back. April 03, 1996 - Midcon Offshore, Inc.
Remarks: Platform operator 1 was cleaning sand and BS&W from the flare scrubber by removing the flange to flange piping and drain valve from the vessel. Operators 2 and 3 were simultaneously initiating production and pressuring up the production separator. The pressure relief valve relieved prematurely through the valve and piping. This pressure surge generated static electricity and ignition. Operator 1 was in the immediate vicinity of the escaping gas and fire and received burns to his face, neck, and arms. The fire scorched the flare scrubber and contact tower, melted the electrical wiring tray, and activated the fire loop system by burning through a TSE, which properly resulted in total platform shut down. April 06, 1996 - Norcen Explorer
Remarks: The platform operator was attempting to start the platform diesel crane engine whose starter is propelled by 140 psi supply gas pressure. The operator sprayed ether into the engine air intake and walked around the side to signal another operator to open the gas start valve. When the first operator checked to see if the engine started, he heard an explosion and a brief flash fire occurred inflicting first and second degree burns on his face. The operator was transferred to a quarters facility and treated by a medic. The burns were considered minor, and the operator declined further medical evaluation at a land-based facility. April 11, 1996 - Mobile Exploration and Producing NA, Inc
Remarks: Employee set air hoist controller on upper cat walk and turned tripping off the lower cat walk. Air hoist was moved causing air hoist controller to fall striking an employee on the right knee. He lost his balance, stumbled against a 4" kick plate on the lower cat walk, and fell 2' to the deck. April 14, 1996 - Mobil Exploration and Producing NA, Inc.
Remarks: Employee was lifting compressor pistons from compressor skid to wash area and then back to the compressor skid. This resulted in an inguinal hernia. April 24, 1996 - Shell Offshore Inc.
Remarks: Crew was tripping pipe in the hole and drill pipe struck roughneck in the face. May 14, 1996 - Union Oil Company of California
Remarks: Two roustabouts were spotting a Francis torque unit when one of them stepped backward and fell through a 4' x 4' open hatch in the top deck. He suffered numerous fractures, contusions, and lacerations. He received immediate first aid and was evacuated for emergency medical aid. May 18, 1996 - Mobil E&P North America Inc.
Remarks: In locating the steam cleaner on the well bay with crane, it hung up on edge of platform. When the unit was freed, it was lowered onto the employee's foot causing his foot and ankle to twist. June 12, 1996 - Seneca Resources Corporation
Remarks: The A-3 well was drilled and completed as a dual gas well and was in the process of being flow tested. The platform operator was unloading sand from the test separator vessel by periodically opening a 1 1/2" manual ball valve located on the bottom of the vessel, while maintaining about 1000# back pressure on the vessel. A mixture of gas and sand continued to cut out the valve and high pressure gas was released to the atmosphere. The natural gas and fluid release came in contact with a fired component and was ignited. The platform safety system operated properly and shut in the wells 1 and 2. Well A-3 was shut in by manually activating the ESD remote located on the test separator. June 15, 1996 - Anadarko Petroleum Company
Remarks: The injured party was stepping down from piping by "A" compressor over to the grating when he lost footing and fell. His injuries consisted of torn ligaments in the right knee, and the left shin was cut to the bone requiring stitches. July 29, 1996 - Murphy Exploration & Production Company
Remarks: The crane operator was using the fast line with a nylon strap to relocate valves to the opposite side of the blowout preventer stack. After hooking up to the valve assembly, they motioned to the crane operator to pick it up slightly, but not completely off the deck. Two personnel applied leverage to turn the valve assembly over. There was slack in the nylon strap causing travel in the fast line ball. The ball struck the wind wall causing a section to fall from the rig floor, and injuring a derrick hand. He received a compound fracture to his leg and a laceration on his shoulder. July 29, 1996 - Stone Energy Corporation
Remarks: Problem with breaker for rig ventilation system. The electrician and motormen began installing copus blowers to keep air compressors cool while rig crew finished pulling out of the hole with bottom hole assembly. Electrician began isolating the panel board. While tightening last bolt, an arc explosion occurred. There were 2 injuries resulting in burns over 20-25 percent of the men's bodies. Austust 08, 1996 - Mobil Exploration & Producing NA, Inc.
Remarks: At some point in time, during the day, the employee incorrectly pushed, pulled, lifted, twisted, bent, or turned. No single event during the day is tied to the injury. September 02, 1996 - Forcenergy Gas Exploration, Inc.
Remarks: An employee was hit by the Kelly hose after a down hole pressure surge. September 08, 1996 - Conoco Inc
Remarks: They were dismantling a section of pipeline riser. The pipeline had been flushed three times with water and had been pigged twice. All the pressure above the shutdown valve had been bled to 0. The riser was disconnected enough at the top to determine that there was no gas in the riser. A rigger was using a torch to cut the remaining studs and bolts off that were partially attaching the shutdown valve to the riser. Hot metal from the cutting torch fell into the open riser below the shutdown valve. Residual hydrocarbons inside the riser ignited and created a flash fire, which burned a portion of the rigger's arm that was exposed to the open top area of the pipeline riser. September 17, 1996 - Texaco Exploration and Production Inc.
Remarks: A drilling rig was being de-mobbed onto a supply workboat. The first lift with the use of the auxiliary (fast line) ball was the grocery box. The grocery box was lowered down to the back deck of the work- boat. The roustabout unhooked the D-ring of the grocery box slings from the auxiliary ball. The roustabout heard a noise as he unhooked the D-ring and looked up. The counter-balance assembly traveled the path of the cable and struck the roustabout in the face and chest. He was air lifted to the hospital. September 18, 1996 - Energy Resource Technology, Inc.
Remarks: A pilot received burns to his arms and to a lesser degree his legs and face due to a flash fire (<1 second) near an oil pump that was being started. Gas used to turn the starter came in contact with a failed shielded ignition device between spark plug and wire. This shielded device was either corroded or had vibrated loose. A cover or cowling obstructed this loose connection from view, therefore, it was not noticed during start-up. September 21, 1996 - Enron Oil and Gas Company
Remarks: Investigation Pending September 30, 1996 - SONAT Exploration Company
Remarks: The wireline operator was in the process of swabbing fluid (water and condensate) into a swab tank through a 2-in flexible rubber/plastic hose that was placed in the open hatch and secured with rope. The platform operator was monitoring fluid returns; and, as he opened the swab tank hatch, a flash fire occurred. The operator's shirt caught fire, and he ran from the swab tank, which remained on fire. Another platform operator extinguished the swab tank fire using two 20# chemical extinguishers. The injured operator sustained serious burns to his face, head, neck, and hands. He was treated onsite with burn packs and brought to the hospital. October 17, 1996 - Anadarko Petroleum Corporation
Remarks: The worker was crossing over a winch boom and stepped on an angle iron, slipped, and fell forward, hitting his right hand on the swing motor of the crane. October 24, 1996 - Enron Oil and Gas Company
Remarks: Personnel were being off-loaded in the personnel basket in bad weather conditions. The basket caught onto an air conditioning unit causing one worker to fall out of the basket, head first. He hit the back of his neck on the air conditioning unit and fell hard onto the deck of the boat. He was flown to the hospital for medical attention. October 29, 1996 - ORYX Energy Company
Remarks: It appears that a short circuit was caused while attempting to connect test clips across the fuse holder. The test clip ends being large and wide shorted together or separately across phases. November 03, 1996 - BHP Petroleum (GOM) Inc.
Remarks: The roustabout was in the process of lubricating the top drive unit for the drilling rig. The worker was hoisted in a boatswains chair to perform this daily task. The third man necessary to provide a communication link between the person performing the work and the air hoist operator was not used. When the air hoist operator lost visual and audible communications, the accident occurred. The roustabout suffered a fractured vertebrae in his upper back along with severe bruising of the shoulder and chest area. He was immediately transported to a hospital for medical attention. November 20, 1996 - Enron Oil and Gas Company
Remarks: While attempting to get off the crane after offloading equipment from the boat, the radiator cap failed, blowing hot coolant on the worker. He jumped off the crane onto the platform deck, injuring the heels of both feet. November 21, 1996 - Mesa Operating Company
Remarks: Injured while disconnecting lubricator and pressure suddenly released. Lubricator lifted one foot causing him to lose balance and fall to deck. Injuries to head, left arm, and right knee. November 22, 1996 - Mesa Operating Company
Remarks: Contractor employee fell when he leaned against a handrail and it gave way. He fell to the walkway below hitting the handrail and continued to fall to the next deck. November 24, 1996 - Amoco Production Company
|