Injuries – 2004 (4 incidents – 4 injuries total)

09-Mar-2004 – Arguello Inc.

MMS Investigation Report:

Completed

Activity:

Exploration

Lease:

P00450

Event(s):

Injury (1)

Area:

Santa Maria

Operation:

Production

Block:

464

Cause:

Slip/Trip/Fall/Human Error

Rig/Platform:

/ Hidalgo

Water Depth:

430 feet

Remarks:  A contract electrician fell approximately 20’ while running cable in an overhead cable tray above the drill floor.  He was transported to the hospital via medivac helicopter for treatment of two broken legs, two broken ankles, and fractures to his left foot. 


25-Jul-2004 – Exxon Mobil Corporation

MMS Investigation Report:

Completed

Activity:

Development / Production

Lease:

P00182

Event(s):

Injury (1)

Area:

6A

Operation:

Production

Block:

5277

Cause:

Slip/Trip/Fall/Human Error

Rig/Platform:

/ Heritage

Water Depth:

1075 feet

Remarks:  A contract employee fell from the rafters approximately 10-12’ while installing new pipe in the pipe rack. The worker had previously disconnected his fall protection gear to crawl between two beams.  As he was attempting to tie off his landyard to the beam, the pipe shifted and he fell from the pipe rack.  He was transported to the hospital via medivac helicopter for stitches and further observation. 


22-Aug-2004 – Arguello Inc.

MMS Investigation Report:

None

Activity:

Development / Production

Lease:

P00315

Event(s):

Injury (1) / Other  - pollution (1 gal./oil)

Area:

Santa Maria

Operation:

Production

Block:

5585

Cause:

Equipment Failure

Rig/Platform:

/ Hidalgo

Water Depth:

675 feet

Remarks:  One gallon of produced water containing a small amount of crude oil was released into the water due to a broken nipple on the produced water line.  The spill resulted in a barely visible sheen (5 yards x 167 yards).  An employee was sent to the hospital with minor injury to his leg from hot water. 


04-Nov-2004 – Plains Exploration & Production Company

MMS Investigation Report:

Completed

Activity:

Development / Production

Lease:

P00234

Event(s):

Injury (1)

Area:

6B

Operation:

Production / Other - construction

Block:

5064

Cause:

Human Error / Slip/Trip/Fall

Rig/Platform:

/ Habitat

Water Depth:

290 feet

Remarks:  A contract employee was climbing up scaffolding to enter the spider basket.  He was wearing a full body harness, life jacket, and other PPE but was not properly tied off.  He stepped onto a plank that had not been properly secured causing the plank to rock back and forth.  He apparently lost his balance and fell approximately 35’ to the water below.  He was able to swim to an access ladder and lift himself onto the platform.  He sustained minor scratches and bruising, and was placed on light duty the next day.